Installation Recommendations cont.

 
page 1 - page 2 - page 3 - page 4
 

Figure No. 37. Minimum Spacing for Cold Water Conduit in Floor Screeds
Conduit in Floor Conduit pipes should be fixed to the sub-floor by using suitable straps to prevent movement. Conduit pipes for cold water systems should not be run in floor screeds which incorporate underfloor heating 'loops'.

Figure No. 38. Conduit Terminal Fittings

HX101/15
Conduit Terminal
HX103
Terminal Back Plate

For terminating the conduit pipe at wall and floor finish level for direct 15mm connections to appliances, a conduit terminal fitting is available (HX101/15). For floor terminations the plastic housing may be drilled through the base to allow fixing. Floor termination procedure is shown in Figure No. 39.

Figure No. 39. HX101/15 Conduit Terminal Instalation Procedure