External
Installations
If
Hep2O®
is installed in an external application then the system will require
protection from frost. Although Hep2O®
has lower thermal diffusivity than copper, insulation requirements
are the same as those of copper and should be in accordance with
BS 5422, BS 6700, Water Byelaws and Building Regulations Approved
Document L.
Hep2O®
pipe is less likely to burst should the water in the pipe freeze,
however should Hep2O®
be connected to a metal pipe, a metal tap or a close configuration
of fittings (incorporating metal support sleeves) then the likelihood
of a failure due to the expansion of frozen water will be increased.
If Hep2O®
is used externally it should be protected from the ultra-violet
radiation in sunlight. If insulation has been installed to avoid
freezing this is sufficient. However, where insulation is not used,
painting or covering is recommended.
|