Connection
to Storage Vessels and Radiators
When connecting Hep2O®
pipe to cylinders, radiators etc. it is always recommended that
Hep2O®
fittings are used wherever possible. The Hep2O®
range of fittings includes thermostatic, wheel head and lockshield
radiator valves, double check valves, tank connectors, gate valves,
stopcocks and cylinder connectors.
If the use of compression fittings is unavoidable then the jointing
instructions outlined in the section, 'Connection Using Compression
Fittings' should be carefully followed.
Do not use any jointing compound on the jointing shoulder of the
cylinder connector, use only PTFE tape. Do not use any jointing
compound when fitting tank connectors, use only sealing washers
(not provided).
Figure No. 56. Tank and Cylinder Connectors
|