Hep2O® Sectioned Tee
 
 
 
 
Hep2O® Logo  
Connection to Ancillaries (Pumps, Valves, etc.)
Figure No. 55 Connection to Pump  

When connecting Hep2O® to ancillaries it is important to follow the guidance in the section 'Connection Using Compression Fittings'. Due to the flexibility of Hep2O® the pipework must be clipped adjacent to the outlets of the pumps and valves using Hep2O® screw pipe clips (code HX85).

This ensures adequate support and reduces vibration in the majority of cases. Where it is felt that the weight of the pump merits extra support, metal brackets should be used.

Where the size of the pump and/or valve requires fixing at a greater distance from the wall than can be accommodated by the pipe clip alone, then this can be augmented with a pipe spacer (HX86), which will allow a greater 'stand-off' distance whilst maintaining security.

 