| Connection
to Ancillaries (Pumps, Valves, etc.) |
| Figure
No. 55 Connection to Pump |
|
|

|
When
connecting Hep2O®
to ancillaries it is important to follow the guidance in the
section 'Connection Using Compression Fittings'. Due to the
flexibility of Hep2O®
the pipework must be clipped adjacent to the outlets of the
pumps and valves using Hep2O®
screw pipe clips (code HX85).
This ensures adequate support and reduces vibration in the majority
of cases. Where it is felt that the weight of the pump merits
extra support, metal brackets should be used.
Where the size of the pump and/or valve requires fixing at a
greater distance from the wall than can be accommodated by the
pipe clip alone, then this can be augmented with a pipe spacer
(HX86), which will allow a greater 'stand-off' distance whilst
maintaining security. |
|
|