Hep2O® Sectioned Tee
 
 
 
 
Hep2O® Logo  

Approvals

Hep2O
® is manufactured and kitemarked to Class S of BS 7291, Parts 1 and 2 and is manufactured within a Quality Management System which satisfies BSEN ISO9002 requirements.

Hep2O® Barrier Pipe is covered by Agreement Certificate 92/2823 to Class 'S' of BS 7291.
BS 7291
Hep2O® Is listed in the Water Fittings and Materials Directory - Listing Number 0112066.
Hep2O® is suitable for use in domestic water distribution and central heating systems including pressurised systems and combination boilers in accordance with Table No. 1. It may also be used in buildings other than dwellings providing the service conditions are not exceeded. Barrier Pipe must be used if British Gas Service Cover is required.

Table No 1. Peak Life Cycle Operating Temperature/pressures

MM 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C Short Malfunction
114°C
Safe pressures:                  
Bar 12 11.5 11 10.5 9 8 7 6 3
psi 174 167 160 152 131 116 102 87 43.5
Head of water (m) 120 115 110 105 90 80 70 60 29

 

 